The minimum size of a sump is 400mm x 200mm minimum width of box gutter and 150mm deep.
Box gutter sump depth.
Starting at the gutter gradient intersection draw a line up the design graph for a freely discharging box gutter chart in your copy of the standard.
Box gutter gradients shall not be flatter than 1 200 for sole widths equal to or less than 600mm wide.
The minimum depth required for the box gutters that make up this roof drainage system is 125 mm.
The outlet must be no further than the diameter of the outlet to the centre of the outlet.
Here is a step wise guide for you to help.
Choose an available dp size or any other size and enter that for the calculation of the sump.
Choose an available size or any other size and enter that for the calculation of the sump.
The depth shown of the box gutter is the depth at the upstream end.
Deviations from the gradient must be smooth and prevent towards the outlet without a proportional permanent ponding.
This will give a sump depth about 150mm.
The suggested down pipe diameter is shown for reference purposes only.
The depth shown of the box gutter is the depth at the upstream end.
To determine the box gutter depth is the first and foremost step for sizing components and materials for the roof drainage system which includes the rain heads and the box gutters.
The line will correspond to a minimum box gutter depth.
The theoretical down pipe diameter is shown for reference purposes only.